EMC Series

Compact and Cost Effective Dual Stage RFI Power Line Filters


UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet
Printer friendly version

 

EMC Series

  • Compact dual stage filter series
  • Cost-effective design
  • Current rating up to 30A
  • High differential mode attenuation in the lower frequency range
  • High common mode performance
  • Suitable for switching mode power supplies

Ordering Information

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

3EMC1 10EMC3
6EMC1 15EMC3
10EMC1 10EMC6
15EMC1 15EMC6
20EMC1 20EMC6
3EMC3 30EMC6
6EMC3  

 

 

Specifications

Maximum leakage current, each Line to Ground:
    3, 6, 10 Amp 15, 20, 30 Amp
  @ 120 VAC 60 Hz .21 mA .73 mA
  @ 250 VAC 50 Hz .43 mA 1.52 mA
     
Hipot rating (one minute):
  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 250 VAC
     
Rated Current: 1A to 30A *
  * refer to part number for rating
Operating Ambient Temperature Range (at rated current Ir):
    -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45

Electrical Schematic

Case Styles

EMC1

Typical Dimensions:
  Line/Load Terminals(4): .250 [6.3] with .07 [1.8] Dia. hole
  Ground Terminal(1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot
  Mounting Holes (2): .187 ±.008 [4.75 ±.20] Dia.

EMC3


Typical Dimensions:  
  Wire leads (5): .4.0 [101.6] Min. AWG18 (AWG16 for 10A)
  Mounting Holes (2): .187 ±.008 [4.75 ±.20] Dia.

EMC6


Typical Dimensions:  
  Terminals (5): 8-32
Torque 18 lbf-in. [2.03 N-m] max. ±2[.22]
  Mounting Holes (2): .187 ±.008 [4.75 ±.20] Dia.

 

 

30EMC6

Typical Dimensions:  
  Terminals (5): 10-32
Torque 27 lbf-in. [3.05 N-m] max. ±3[.34]
  Mounting Slots (4): .203 x .156 [5.16 x 3.96]

Case Dimensions

Part No. A B C D E
(max.) (max.) (max.) (max.) (max.)
3EMC1 3.35 1.81 1.16 2.375 2.78
85.1 46.0 29.5 60.3 70.6

6EMC1, 10EMC1 3.85 2.07 1.16 2.938 3.35
97.8 52.6 29.5 74.6 85.1

15EMC1, 20EMC1 4.97 2.25 1.78 4.063 4.46
126.2 57.2 45.2 103.2 113.3

3EMC3 2.07 1.81 1.16 2.375 2.78
52.6 46.0 29.5 60.3 70.6

6EMC3 2.56 2.07 1.16 2.938 3.35
65.0 52.6 29.5 74.6 85.1

10EMC3 2.56 2.07 1.53 2.938 3.35
65.0 52.6 38.9 74.63 85.1

15EMC3 3.69 2.25 1.78 4.063 4.47
93.7 57.2 45.2 103.2 113.5

10EMC6 3.94 2.07 1.53 2.938 3.35
99.9 52.6 38.9 74.6 85.1

15EMC6, 20EMC6 5.09 2.25 1.78 4.063 4.47
129.3 57.2 45.2 103.2 113.5

30EMC6 6.05 3.12 2.18 3.50 3.96
153.7 79.2 55.4 88.9 100.6

 

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
 

3EMC

6EMC

10EMC

15EMC

20EMC

30EMC

   
Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)   Differential Mode / Symmetrical (Line to Line)

 
Current Rating Frequency - MHz
.05 .07 .11 .15 1 2 10 20 30

3A 6 6 3 16 65 66 62 60 59
6A 6 6 2 15 65 67 65 62 63
10A 5 2 13 24 72 72 56 50 48
15A 3 1 12 22 70 68 57 54 53
20A 2 2 11 21 58 57 63 55 52
30A 2 2 14 22 47 52 60 48 43

 
Current Rating Frequency - MHz
.05 .07 .11 .15 1 2 10 20 30

3A 12 13 7 18 64 69 65 60 52
6A 12 12 8 27 61 61 59 56 54
10A 14 15 12 33 54 58 47 34 36
15A 16 16 13 34 61 52 36 36 23
20A 17 19 15 37 67 62 36 32 30
30A 17 18 14 40 62 53 30 28 26

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.