Skip to content
Home > Series > Power Line > DK

DK Series

Enhanced Differential Mode Performance K Series RFI Line Filter


UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet
Printer friendly version

 

DK Series

  • Higher performance Line to Line attenuation than the K Series
  • E version meets the low leakage current requirements of VDE portable equipment and non-patient care equipment
  • V version features same high performance
    with more cost-effective design

Ordering Information

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

1VDK1 1EDK1
1VDK3 1EDK3
3VDK1 3EDK1
3VDK3 3EDK3
6VDK1 6EDK1
6VDK3 6EDK3
10VDK1 10EDK1
10VDK3 10EDK3
20VDK1 20EDK1
20VDK6

 

 

Specifications

Maximum leakage current, each Line to Ground:
    VDK Models EDK Models
  @ 120 VAC 60 Hz .4 mA .22 mA
  @ 250 VAC 50 Hz .7 mA .38 mA
     
Hipot rating (one minute):
  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 250 VAC
     
Rated Current: 1A to 20A *
  * refer to part number for rating
Operating Ambient Temperature Range (at rated current Ir):
    -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45

Electrical Schematic

Case Styles

VDK1 / EDK1

Typical Dimensions:
  Line/Load Terminals(4): .250 [6.3] with .07 [1.8] Dia. hole
  Ground Terminal(1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot
  Mounting Holes (2): .188 [4.75] Dia.

 

VDK3 / EDK3

Typical Dimensions:  
  Wire leads (5): .4.0 [101.6] Min. AWG18 (AWG16 for 10A)
  Mounting Holes (2): .188 [4.75] Dia.

 

20VDK1 / 20EDK1

Typical Dimensions:
  Line/Load Terminals(4): .250 [6.3] with .07 [1.8] Dia. hole
  Ground Terminal(1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot
  Mounting Holes (2): .188 [4.75] Dia.

 

 

20VDK6

Typical Dimensions:  
  Terminals (5): 8-32
Torque 18 lbf-in. [2.03 N-m] max. ±2[.22]
  Mounting Holes (2): .188 [4.75] Dia.

 

Case Dimensions

Part No. A B C D E
(max.) (max.) (max.) ± .015 (max.)
± .38
1VDK1, 1EDK1 3.35 2.07 1.16 2.375 2.81
85.1 52.6 29.5 60.33 71.4

1VDK3, 1EDK3 2.07 2.07 1.16 2.375 2.81
52.6 52.6 29.5 60.33 71.4

3VDK1, 3EDK1,
6VDK1, 6EDK1
3.85 2.07 1.16 2.938 3.35
97.8 52.6 29.5 74.63 85.1

3VDK3, 3EDK3,
6VDK3, 6EDK3
2.56 2.07 1.16 2.938 3.35
65.0 52.6 29.5 74.63 85.1

10VDK1, 10EDK1 3.85 2.07 1.32 2.938 3.35
97.8 52.6 33.5 74.63 85.1

10VDK3, 10EDK3 2.57 2.07 1.32 2.938 3.35
65.3 52..6 33.5 74.63 85.1

20VDK1, 20EDK1 3.85 2.58 1.78 2.938 3.35
97.8 65.5 45.2 74.63 85.1

20VDK6 3.46 2.58 1.78 2.938 3.35
87.9 65.5 45.2 74.63 85.1

 

 

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
 

1 & 3VDK

6, 10, 20 VDK

1 & 3EDK

6, 10, 20 EDK

Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)   Differential Mode / Symmetrical (Line to Line)

 

Current Rating

Frequency - MHz
.15 .5 1 5 10 30

VDK Models
1A, 3A 18 30 40 48 48 40
6A, 10A, 20A 10 22 30 39 44 50
EDK Models
1A, 3A 17 27 33 45 45 40
6A, 10A, 20A 10 19 25 34 40 46

 
Current Rating Frequency - MHz
.15 .5 1 5 10 30

VDK, EDK Models
1A, 3A 18 47 62 60 50 45
6A, 10A, 20A 20 43 55 65 60 55

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.