Skip to content
 |  Tyco Electronics Segment Indicator  |   | 
Tyco Electronics - Our commitment. Your advantage.
Visit www.tycoelectronics.com Corcom Products
Home > Series > PEM > P

P Series

The CHAMELEON Adaptable Module for General, High Performance or Medical Applications

UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet

P Series

The P series power entry module offers fuller flexibility of design in a more compact package.

As the first 10 amp module to provide all five power entry functions in one compact design, the CHAMELEON module readily adapts to its environment and the needs of international markets.

  • Snap-in or flange mounting
  • IEC power line connector
  • Both North American and European fusing capabilities
  • Two voltage selections
  • Optional DPST on/off switch
  • Filtering options for general purpose, medical and high-performance applications.

The CHAMELEON modules compact design and modular construction will allow you to select the power entry features you require — without altering the panel cutout. And the Chameleon module, with adapters, will fit any standard panel cutout.

The CHAMELEON module has four filter options.

S models offer protection for general purpose applications where line-to-ground and line-to-line noise must be controlled. The filters are designed to meet low leakage requirements of VDE portable equipment. They are available in current ratings of 3, 6 and 10 amps.

H models provide susceptibility protection without leakage current associated with line-to-ground capacitors and are designed to allow equipment to meet UL 544 for patient care and non-patient care equipment.

Also available is an interconnection block, B models. The block connects the voltage selection terminals of an unfiltered CHAMELEON module with a switch and an IEC connector to reduce external wiring.

L Models – High performance medical filter versions that are designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC part 15J, Class B) conducted emissions limits while additionally allowing equipment to meet UL544, UL2601and EN60601 for patient care equipment and non-patient care equipment. They are available with current ratings of 6 and 10 amps. High performance versions are available with horizontal and vertical mounting ears, single voltage, complete can shield with options for switch, fuses and current ratings only. Extenders are not available.

Z Models – High performance filter versions are designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10 amps. High performance versions are available with horizontal and vertical mounting ears, no extenders, single voltage, complete can shield with options for switch, fuses and current ratings only.

See Appendix C for more information on UL544 or UL2601 health care applications.

Note: When using the models with an IEC connector, remember that the leakage current of the companion line cord, GA400, is more significant than that of the filter - which may disqualify this line cord from use in patient care applications.

Electrical Schematic

H Model

S Model

L Model

Z Model

Resistor location for reference only

PE Filter with "A" Shield

Specifications

Maximum leakage current, each line to ground :
    H & L
Models
S & Z
Models
  @ 120 VAC 60 Hz: 2 µA .25 mA
  @ 250 VAC 50 Hz
5 µA .50 mA
     

Hipot rating (one minute):

  line to ground 1500 VAC
  line to line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated Voltage (max.): 250 VAC
     
Operating voltages: Selectable or Fixed
115 or 230 VAC
     
Rated Current: Unfiltered 10 Amps
  Filtered - 3, 6 or 10 Amps
  * refer to part number for rating
   
Fuse (not included):

Accepts one or two fuses
.25" x 1.25" or 5 x 20mm
Conversion clip provided on fuseholder for single fuse models

   
Switch:

Double-insulated, rated for 10,000 operations at full load.
51 Amp inrush capability

   
Terminals:
Standard Versions: .187 x 0.032
4.8 x .81
High Performance Versions: .250 x 0.032
6.4 x .81
Recommended for use with mating connector, no solder
 
  † Filtered models only
Minimum insertion loss in dB:
Line to ground in 50 ohm circuit

Current Rating Frequency - MHz
.03 .1 15 .5 1 3 5 10 30

H Models
3A 7 17 21 27 30 29 26 23 15
6A - 8 11 15 17 19 18 16 13
10A 3 5 8 10 12 11 11 10 10
S Models
3A 7 17 21 27 33 40 44 50 32
6A - 8 12 17 23 32 36 44 30
10A - 3 5 10 13 23 27 35 27

Current Rating Frequency - MHz
.01 .05 .1 .15 .5 1 5 10 30

Z Models
6A 8 21 27 30 37 43 49 52 42
10A 5 17 22 24 27 32 52 47 40
L Models
6A 8 21 27 29 34 35 25 21 16
10A 5 17 22 23 24 25 21 18 14

 
Line to line in 50 ohm circuit

Current Rating Frequency - MHz
.10 .15 .5 1 3 5 10 30  

H Models
3A 2 4 12 18 31 40 48 41  
6A 2 4 12 16 26 35 40 35  
10A 2 4 12 16 26 33 40 32  
S Models
3A 2 4 12 15 30 48 50 45  
6A 2 4 12 15 22 42 55 45  
10A 2 4 12 15 22 42 55 45  

Current Rating Frequency - MHz
.01 .05 .1 .15 .5 1 5 10 30

Z Models
6A 10 15 34 44 75 75 75 70 60
10A 10 20 20 35 67 75 75 70 60
L Models
6A 10 15 34 44 75 75 75 70 60
10A 10 20 20 35 67 75 75 70 60

 

 

P Series Part Numbering Schematic

Part numbers are constructed by selecting the alphanumeric character which represents the desired feature

The part number PSJ0XSS60 would represent the equivalent of the Corcom J Series 6J4
P
S
J
0
X
S
S
6
0
P Series
with a snap-in mount
with the J extender to fit the 6J4 cutout
and includes no switch
dual voltage select
single fusing
general purpose filter
for 6 amps
with no shield
P Series Configuration Search
Enter a full or partial part number to search
Partial searches may take several seconds
Notes:
  An additional extender which allows the P series to adapt to Corcom's L series product cutout as well as the panel cutout of Schaffner and Delta parts is also available.
* Extenders cannot be added to units with B shields
†  When using the interconnection block, the last 3 digits of the part number are BX (0, A, or B)
‡  For alternative switch orientation options, please contact technical support or your Corcom sales representative
** Dual voltage options are not available with L or Z Filter Types
*** High performance versions are available with horizontal (PE style) or vertical (PM style) mounting ears, no extenders, single voltage, complete can shield with options for switch, fuses, filter type (L or Z) and 6 or 10 amp current ratings only.
Voltage Selection

The P series of power entry modules provides a dual voltage selector which is integrated with the fuseholder. To simplify the wiring in each individual application, Tyco Electronics provides dedicated voltage selectors for different voltage selection schemes. The two most popular schemes are the parallel and serial for dual primary transformers and the “DPST switch” for switching mode power supplies (jumper types.) P series products with an “S” as the fifth digit are specifically designed for “jumper” type applications associated with switching mode power supplies. P series products with an “X” as the fifth digit are specifically designed for dual primary transformer applications. The voltage selector installed will allow proper wiring from these applications. No matter what voltage selection scheme is used, wiring is always made to the same four terminals.

X - Dual Primary Transformer Type

S - Jumper Type

Note 1: Jumpers are required if a filter or interconnection module is not used.
Note 2: Location of optional filter. Jumpers are required if a filter or interconnection block is not used

Shield

A new feature available on the P series is an RF shield. The metal shield, available on filtered models, provides shielding from radiated emissions and provides an additional RF ground for the filter to the case. The shield is available in two versions, a shield of the filter components (designated by A as the ninth digit) and a complete shield (designated by B as the ninth digit). The A shield covers the filter portion of the module and increases performance of the filter by protecting the components from magnetic coupling. This shield improves RF ground connection to the case while still allowing the use of the P Series extender. The B shield covers the entire power entry module with metal, protecting the equipment from all radiated noise. Used with the filter, the shield provides the most secure protection from RFI noise problems. The B shield cannot be used with any extender.

Fuseholder

Another feature of the P series power entry module is a versatile fusing arrangement. Its fuseholder can hold two 1/4” x 1-1/4” or 5 x 20mm fuses. It can also be converted to accept one fuse with a conversion clip that bridges one of the two fuse chambers. The conversion clip is installed on the P Series power entry modules set for single fusing (those with part numbers with an “S” as the sixth digit). Units with a “D” as the sixth digit do not include a conversion clip.

Conversion clip included for use in single fuse applications

 

Fuseholder shown with 5x20mm fuse

Interconnection Block

Also available is an interconnection block (B models). The block connects the voltage selection terminals of an unfiltered CHAMELEON module with a switch and an IEC connector to reduce external wiring. Installation of the unfiltered versions of the P series involves wiring of the IEC socket to the switch and the switch to the fuseholder. Labor can be eliminated by ordering the product with an interconnection block. This feature, designated by a BX in the seventh and eighth digits, pre wires the module for easier installation. The wiring is protected with the plastic case to better prevent access to the terminals and connections. The dimensions of this alternative are the same as the filtered versions.

Accessories

A full range of accessories are available for the P Series. To simplify customer installation wiring can be simplified by ordering a PA100 connector assembly which is pre-wired with 6" of wire lead. See the P Series Accessory page for a complete list of all accessories available for this series.

PA100 Connector Assembly

Case Styles

PS / PSL

STP Files *
PS Unfiltered PS Filtered PS with A Shield PS with B Shield

PE

STP Files *
PE Unfiltered PE Filtered PE with A Shield PE with B Shield

 

PM

STP Files *
not available at this time not available at this time
PM Unfiltered PM Filtered PM with A Shield PM with B Shield

 

 

PSC / PSJ

Note 1: For snap-in applications, the D sides of the cutou must have a .02 [.508] radius on the installation side.
Snap-in models allow front mouting only. Not recommended for plastic panels

Typical Dimensions
Terminals: .187 x 0.032 Holes: .055 Dia ± .004
4.8 x .81 1.5 ± .10
Slot: .06 x .115 ± .004 Mounting Holes (PE, PM Only)
Countersunk
.135 Dia
1.52 x 2.92 ±.10 3.43

PE High Performance

Refer to PE for cutout drawing and table for PE High Performance dimensions

STP Files *
PE High Performance

PM High Performance

 

Refer to PM for cutout drawing and table for PM High Performance for dimensions

Typical Dimensions
Terminals: .250 x 0.032 Holes: .07
6.4 x .81 1.8
Slot: .07 x .16 Mounting Holes
Countersunk
.135 Dia
1.8 x 4.1 3.43

* .STP files can be imported as 3D models into most CAD systems.
Files are compressed in .zip format for easy download

 

Removal of Fuseholder

Step One

Using a pocket screwdriver, insert the screwdriver in the slot under the door and gently rotate the screwdriver to unlatch the door. When unlatched, raise the door and proceed with step two.

Step Two

With the door in the raised position, apply the screwdriver at the slot in the end of the fuseholder and gently push down to raise the fuseholder and remove it from the housing.

Download PDF version

 

Shielding

Shields can be used only with filtered models
Shields add approximately 0.06" to depth
B Sheild may not be used with J or C Extender

Rear View

Case Dimensions

Part No. A B1 B2 C D E F
(max.) (max.) (max.) (max.) see ¹ see ¹ (ref)

PS

1.24 1.93 2.13 2.31 1.06Δ 2.201 *  
31.49 49.02 54.1 58.67 26.93 55.91  

PSL

1.24 1.93 2.13 2.31 1.12 2.201 *  
34.49 49.02 54.1 58.67 28.45 55.91  

PE

1.98 1.93 2.13 2.31 1.122 2.201 * 1.575
50.29 49.02 54.1 58.67 28.5 55.91 40.0
PM 1.24 1.93 2.13 2.9 1.06 2.13 2.496
31.49 49.02 54.1 73.66 26.93 54.1 63.4

PSC

1.24 1.93 2.13 2.51 1.06 2.52  
31.49 49.02 54.1 63.75 26.93 64.01  

PSJ

1.24 1.93 2.13 2.72 1.06 2.6  
31.49 49.02 54.1 69.09 26.93 66.0  

PE
High Performance

1.98   4.42 2.31 1.12 2.201 1.575
50.29   112.27 58.67 28.5 55.91 40.0

PM
High Performance

1.2   4.4 2.31 1.12 2.201 2.9
30.48   112.27 58.67 28.5 55.91 73.66

¹ +.008/-.000 [+.20/-.00]
* Panel cutout for thickness of .031 - .079 [0.8-2.0] For panel thickness at .083-.114 [2.1-2.9] use 2.213 [56.21]
† Panel cutout for thickness of 0.06 - 0.09 [0.76 - 2.29]
Δ For shielded models use D=1.12 +.008/-.000 
Shields can be used only with filtered models
USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.