M Series

Power Entry Module with Optional RFI Power Line Filter for General and Medical Applications

UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet

M Series

The M series power entry modules offer the most choices of power entry components and filtering options to fit a specific need. The fully configured M series expands the options of a manufacturer whose products are marketed worldwide. One component, fully assembled and tested, provides the capability of interfacing a multi-voltage power supply to any common voltage or fusing scheme in the world, without modification.

  • The IEC connector provides an internationally accepted power entry termination, which can be used with a variety of line cords.
  • The selectable fuseholder allows use of single or dual European fuses, or a single North American fuse.
  • The optional DPST on/off switch breaks both sides of the line and is labeled with the international I/O markings.
  • The optional voltage selector provides a convenient means to change transformer primary connection, and it is available in both 2-voltage and 4-voltage configurations.
  • The series is available with four filter circuits to meet a variety of applications, and convenient connections are provided on unfiltered models to allow wiring of a separate RFI filter.

The M series is a family of components offering greater flexibility and cost-effectiveness in the selection of primary power components. Wiring to the modules is accomplished via .110” terminals for labor savings and convenience. Four filter circuits provide a choice of attenuation tailored to specific categories of susceptibility and emissions needs.

HM Models – This medical filter provides susceptibility protection without the leakage current associated with line-to-ground capacitors. Designed to allow equipment to meet UL544 for patient care and non-patient care equipment, the HM filter has a maximum leakage current of 2 μA at 120 VAC 60 Hz.

FM Models – General purpose RFI filter designed for susceptibility applications, effectively providing RFI control of line-to-ground noise. The design is compact and meets the very low leakage current requirements of VDE portable equipment as well as (120 Volt) UL544 non-patient medical equipment.

XM Models – High performance RFI filter designed to bring most digital equipment (including switching power supplies) into compliance with FCC Part 15J, Class B conducted emissions limits.

ZM Models – Premium RFI filter designed to bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits.

See Appendix C for more information on UL544 or UL2601 health care applications.

Note: When using the models with an IEC connector, remember that the leakage current of the companion line cord, GA400, is more significant than that of the filter - which may disqualify this line cord from use in patient care applications.

 

Voltage Selection

To change selected voltage: open cover, using small blade screwdriver or similar tool; set aside cover/fuse block assembly; pull voltage selector card straight out of housing, using indicator pin; orient selector card so that desired voltage is readable at the bottom; orient indicator pin to point up when desired voltage is readable at bottom (note that when indicator pin is fixed, successive voltages are selected by rotating the card 90° clockwise); insert voltage selector card into housing, printed side of card facing forward toward IEC connector and edge containing the desired voltage first; replace cover, and verify that indicator pin shows the desired voltage.

Voltage Selector Card Orientation

 

Electrical Schematic

VM - 1 Voltage

click on image for larger view

VM - 2 Voltage

click on image for larger view

VM - 4 Voltage

click on image for larger view

Note 1: Jumpers required if no input filter is used
Note 2: Provision for dual European style fusing
Note 3: On/Off switch present only with "S" suffix
Note 4: When using a center tapped transformer, the C-F winding should be the low voltage (high current) winding and must be capble of handling the full primary current in the 120V position

 

FM & HM - 1 Voltage

click on image for larger view

FM & HM- 4 Voltage

click on image for larger view

XM & ZM - 1 Voltage

click on image for larger view

XM & ZM - 4 Voltage

click on image for larger view

Note 1: Provision for dual European fusing
Note 2: Power on/off switch with suffix "S" only
Note 3: HM models without line-to-ground capacitors
Note 4: Modesl HM4, FM4, XM4 and ZM4 have added terminals K and L. External switch or jumper must be placed from K to H and L to J

230V nomenclature relates to pending European CENELEC agreement.

Resistor location for reference only

Specifications

Maximum leakage current, each line to ground :
    HM
Models
FM
Models
XM / ZM
Models
  @ 120 VAC 60 Hz: 2 µA .25 mA .30 mA
  @ 250 VAC 50 Hz
5 µA .50 mA .50 mA
     

Hipot rating (one minute):

  line to ground 1500 VAC
  line to line 1450 VDC
  line to load
(switch off)
Unfilterd only
2500 VAC
     
Operating Frequency: 50 / 60 Hz
     
Rated Voltage (max.): 250 VAC
     
Operating voltages: 100, 120, 220, 240 VAC
     
Rated Current: 3 to 5 Amps
  * refer to part number for rating
   
Fuse (not included):

Reversible fuseholder
Accepts one .25" x 1.25"
or two fuses 5 x 20mm

   
Switch:

Double-insulated, rated for 100,000 operations at full load.
70 Amp inrush capability

   
Terminals: .110 [2.79]
 
Minimum insertion loss in dB:
Line to ground in 50 ohm circuit

Current Rating Frequency - MHz
.01 .05 .15 .5 1 5 10 30    

HM
5A - - 14 18 19 22 22 17    
FM
5A - - 14 21 26 40 45 40    
XM
3A 2 13 23 40 46 44 44 44    
ZM
3A 15 29 39 46 43 40 40 40    

 
Line to line in 50 ohm circuit

Current Rating Frequency - MHz
.02 .03 .05 .07 .15 .5 1 5 10 30

XM
3A - - - 5 34 62 68 60 50 40
ZM
3A 5 13 28 37 55 75 75 62 54 44

 

Fuse Installation Instructions

1. Remove power cord.
2. Pry door open at socket.
3. Lift and swing door into socket.
4. Lift fuse holder out of housing.
5. Install one (1) AG fuse or two (2) metric fuses*.
6. Replace fuse holder into housing.
7. Swing and snap door back in place.

Removing the Fuse Holder (download pdf version)

1. Insert a pocket screwdriver at point "X" as shown

Gently lift UP until the entire door lifts up approximately 1/4" (minimum)

2. Once lifted, the door will pivot on it's hinges and expose the fuse holder

3. When the fuse holder is installed in the single fuse position, apply the screwdriver as shown and gently pry up. Insert screwdriver as shown - do not use fingers to pry unit loose.

When the fuse holder is installed in the dual fuse position, it will normally release as soon as the door is opened.

Fuse Changing

European Fusing Arrangement **

North American Fusing Arrangement **

** Install fuses on one side only. Do not install both AG and Metric fuses at the same time.

See the M Series Accessory page for a complete list of all accessories available for this series.

Case Styles - Filtered

3EXM1S & 3EZM1S
(IEC Connector, DPST On/Off Switch, Selectable Fuseholder)

3EXM4& 3EZM4
(IEC Connector, Voltage Selector, Selectable Fuseholder)

3EXM4S & 3EZM4S
(IEC Connector, DPST On/Off Switch, Voltage Selctor, Selectable Fuseholder)

5EHM1 & 5EFM1
(IEC Connector, Selectable Fuseholder)

5EFM1C
(IEC Connector, Selectable Fuseholder, Snap-In)

5EHM1S & 5EFM1S
(IEC Connector, DPST On/Off Switch, Selectable Fuseholder)

5EHM1SC
(IEC Connector, DPST On/Off Switch, Selectable Fuseholder, Snap-In)

5EHM4& 5EFM4
(IEC Connector, Voltage Selector, Selectable Fuseholder)

5EFM4C
(IEC Connector, Voltage Selector, Selectable Fuseholder, Snap-In)

5EHM4S & 5EFM4S
(IEC Connector, DPST On/Off Switch, Voltage Selctor, Selectable Fuseholder)

5EFM4SC
(IEC Connector, DPST On/Off Switch, Voltage Selector, Selectable Fuseholder, Snap-In)

Case Styles - Unfiltered

6VM1
(IEC Connector, Selectable Fuseholder)

6VM1C
(IEC Connector, Selectable Fuseholder, Snap-In)

6VM1S
(IEC Connector, DPST On/Off Switch, Selectable Fuseholder)

6VM1SC
(IEC Connector, DPST On/Off Switch, Selectable Fuseholder, Snap-In)

6VM2S & 6VM4S
(IEC Connector, Voltage Selector, Selectable Fuseholder)

6VM4C
(IEC Connector, Voltage Selector, Selectable Fuseholder, Snap-In)

6VM4SC
(IEC Connector, DPST On/Off Switch, Voltage Selector, Selectable Fuseholder, Snap-In)

Typical Dimensions
Terminals: .110

Holes
except solder lug ground tap with wire wrap

.055 ± .004
.270 1.5
Mounting Holes: .155 Mounting holes on tabs are countersunk and take a #6 flathead screw
3.94

Recommended Panel Cutouts

Flange Mount

Snap-In

Panel Thickness: .06 - .09 [1.53 - 2.29

Case Dimensions

Part No. A B C D E F G
(max.) ±0.01 (max.) (max.) (max.) (ref) (ref)
±0.038

3EXM1S, 3EZM1S

4.17 3.62 1.14 3.22 1.72 3.28 3.3
105.9 91.9 29.0 81.8 43.7 83.8 83.8

3EXM4, 3EZM4

3.88 3.32 1.14 2.92 1.72 2.98 2.99
98.6 84.3 29.0 74.2 43.7 75.7 75.9

3EXM4S, 3EZM4S

4.65 4.1 1.14 3.72 1.72 3.76 3.8
118.1 104.1 29.0 94.5 43.7 95.5 96.5
5EFM1, 5EHM1 3.39 2.84 1.14 2.44 2.19 2.5  
86.1 72.1 29.0 62.0 55.6 63.5  

5EFM1C

2.56   1.14 2.44 2.19 2.49  
65.0   29.0 62.0 55.6 63.2  

5EFM1S, 5EHM1S

4.17 3.62 1.14 3.22 2.19 3.28  
105.9 91.9 29.0 81.8 55.6 83.3  

5EFM1SC

3.34   1.14 3.27 2.19 3.27  
84.8   29.0 83.1 55.6 83.1  
5EFM4, 5EHM4 3.88 3.32 1.14 2.92 2.19 2.98  
98.6 84.3 29.0 74.2 55.6 75.7  

5EFM4C

3.04   1.14 2.92 2.19 2.97  
77.2   29.0 74.2 55.6 75.4  

5EFM4S, 5EHM4S

4.65 4.1 1.14 3.7 2.19 3.76  
118.1 104.1 29.0 94.0 55.6 95.5  

5EFM4SC

3.82   1.14 3.7 2.19 3.75  
97.0   29.0 94.0 55.6 95.3  
6VM1 3.39 2.84 1.14 2.44 1.45 2.5  
86.1 72.1 29.0 62.0 36.8 63.5  

6VM1C

2.56   1.14 2.44 1.45 2.5  
86.1   29.0 62.0 36.8 63.2  

6VM1S

4.17 3.62 1.14 3.22 1.45 3.28  
1015.9 91.9 29.0 81.8 36.8 83.3  

6VM1SC

3.34   1.14 3.27 1.45 3.27  
84.8   29.0 83.1 36.8 83.1  

6VM2, 6VM4

3.88 3.32 1.14 2.92 1.45 2.98  
98.6 84.3 29.0 74.2 36.8 75.7  

6VM4C

3.04   1.14 2.92 1.45 2.97  
98.6   29.0 74.2 36.8 75.4  

6VM2S, 6VM4S

4.65 4.1 1.14 3.72 1.45 3.76  
118.1 104.1 29.0 94.5 36.8 95.5  

6VM4SC

3.82   1.14 3.7 1.45 3.75  
97.0   29.0 94.0 36.8 95.3  

Part Numbers

Click on any part number for distributor stock status and eCommerce Links. For more information refer to the Corcom Part Numbering System reference.


FILTERED Models

Part Number Filter Type Current Rating @120VAC (Amps) Current Rating @ 250VAC (Amps) Available Voltage Selection Positions † DPST On/Off Switch Mounting Style

3EXM1S SMPS FCC-B ¹ 3 2 1 Flange
3EXM4 SMPC FCC-B ¹ 3 2 4   Flange
3EXM4S SMPC FCC-B ¹ 3 2 4 Flange
3EZM1A SMPS EN55022-B ² 3 2 1 Flange
3EZM4 SMPS EN55022-B ² 3 2 4   Flange
3EZM4S SMPS EN55022-B ² 3 2 4 Flange
5EHM1 Medical³ 5 4 1   Flange
5EHM1S Medical³ 5 4 1 Flange
5EHM4 Medical³ 5 4 4   Flange
5EHM4S Medical³ 5 4 4 Flange
5EFM1 General Purpose ‡ 5 4 1   Flange
5EFM1C General Purpose ‡ 5 4 1   Snap-In
5EFM1S General Purpose ‡ 5 4 1 Flange
5EFM1SC General Purpose ‡ 5 4 1 Snap-In
5EFM4 General Purpose ‡ 5 4 4   Flange
5EFM4C General Purpose ‡ 5 4 4   Snap-In
5EFM4S General Purpose ‡ 5 4 4 Flange
5EFM4SC General Purpose ‡ 5 4 4 Snap-In

• Includes DPST Switch

UNFILTERED Models
Part Number Current Rating @120VAC (Amps) Current Rating @ 250VAC (Amps) Available Voltage Selection Positions † DPST On/Off Switch Mounting Style

6VM1 6 6 1   Flange
6VM1C 6 6 1   Snap-In
6VM1S 6 4 1 Flange
6VM1SC 6 4 1 Snap-In
6VM2 6 6 2   Flange
6VM2S 6 6 2 Flange
6VM4 6 6 4   Flange
6VM4C 6 6 4   Snap-In
6VM4S 6 4 4 Flange
6VM4SC 6 4 4 Snap-In

• Includes DPST Switch

Includes DPST Switch
1- 120V/240V Fixed, 2 - 120/240V Selectable, 4- 100, 120, 230, 240V Selectable
¹ Emissions filter for switching power supply applications where FCC-B level requirements must be met
² Emissions filter for switching power supply applications where EN5502-B level requirements must be met
³ Medical filter for very low leakage UL UL544, UL2601 and EN60601 health care applications
‡  General purpose filter for susceptibility applications

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.