Skip to content
 |  Tyco Electronics Segment Indicator  |   | 
Tyco Electronics - Our commitment. Your advantage.
Visit www.tycoelectronics.com Corcom Products
Home > Series > PEM > LA

LA Series

Multi-Function Power Entry Modules with RFI Power Line Filters

UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet

LA Series

The LA series is a multi-function power entry connector with a choice of filtering capabilities. The series features an IEC power line connector, selectable North American or dual European fusing capabilities, DPST on/off switch, and 120/240 voltage selection. The filtered LA units provide a one piece solution to power entry needs and provide a filtering solution for almost any RFI problem. Their vertical design is flange mounted.

This series offers three levels of filtering, all carrying UL recognition, CSA certification, and VDE approval.

FLA Model

General purpose RFI filter designed for susceptibility applications, effectively providing RFI control of line-to-ground noise.

XLA Model

High performance RFI filter designed to bring most digital equipment (including switching power supplies) into compliance with FCC Part 15J, Class B conducted emissions limits.

ZLA Model

Premium performance RFI filter designed to bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits.

Electrical Schematic

FLA

XLA & ZLA

Note: Provision for dual European fusing by connection to "A"

Resistor location for reference only

Voltage Selection

To change selected voltage: remove the fuse cartridge using a small blade screwdriver or similar tool; select the desired voltage by matching the arrow on the fuse cartridge to the arrow located on the front of the unit (lower right corner); replace the fuse cartridge making sure the voltage selection arrow aligns with the arrow located on the front of the unit.

Fuse Changing

Remove the fuse cartridge using a small blade screwdriver or similar tool; for European fusing pull out the sliding fuse covers located at the top of each fuse compartment; insert desired fuses; push the sliding fuse covers back in place and insert the fuse cartridge back into the unit making sure the voltage selection arrow aligns with the arrow located on the front of the unit. (Note: Single North American or European fuse placement is always on the side of the desired voltage selection arrow behind the fuse symbol; the other compartment may be used as a spare or be left blank. Dual European fusing capability is available for 220/240 volts only.)

 

Specifications

Maximum leakage current, each line to ground:
    FLA
Models
XLA / ZLA
Models
  @ 120 VAC 60 Hz: .25 mA .30 mA
  @ 250 VAC 50 Hz
.50 mA .50 mA
     
Hipot rating (one minute):
  line to ground (VAC) 1500 VAC
  line to line (VDC) 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Operating voltages: 110, 120, 220, 240 VAC
     
Rated Voltage (max.): 250 VAC
     
Rated Current: 3 to 5 Amps
  * refer to part number for rating
Switch:

Doube-insulated, rated for 50,000 operations at full load. 35 Amp inrush capability

   
Fuse (not included):

Accepts one .25" x 1.25" fuse or two 5 x 20 mm fuses

   
Terminals: .110 [2.79] terminals
   
Minimum insertion loss in dB:
Line to ground in 50 ohm circuit

Current Rating Frequency - MHz
.01 .05 .15 .5 1 5 10 30    

FLA
5A - - 14 21 26 40 46 50    
XLA
3A 2 12 21 35 46 44 44 40    
ZLA
3A 14 28 38 42 40 40 40 40    

 
Line to line in 50 ohm circuit

Current Rating Frequency - MHz
.02 .03 .05 .07 .15 .5 1 5 10 30

XLA
3A - - - 5 33 60 65 60 50 50
ZLA
3A 3 14 29 38 57 72 72 65 55 50

 

 

Case Styles

 

 

Typical Dimensions
Terminals: .110 Holes:
except solder lug ground tap with wire wrap
.059 Dia.
4.80 1.5
    Mounting Holes (2)
.142 Dia
  3.6

Recommended Panel Cutout

All models allow front mounting only

Case Dimensions

Part No. A B C D E F
(max.) ± .15 (max.) (max.) (max.) (max.)
± .381

5EFLA2S

1.99 1.57 2.59 2.41 3.16 1.18
50.5 39.9 65.79 61.21 68.07 29.97

3EXLA2S 1.99 1.57 2.59 2.41 4.16 1.18
50.5 39.9 65.79 61.21 105.7 29.97

3EZLA2S 1.99 1.57 2.59 2.41 4.16 1.18
50.5 39.9 65.79 61.21 105.7 29.97

 

Part Numbers

Click on any part number for distributor stock status and eCommerce Links. For more information refer to the Corcom Part Numbering System reference.

5EFLA2S
3EXLA2S
3EZLA2S

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.